This arrival, photographed in our warehouse: one Metso ND9303HX smart valve positioner. The model belongs to the Neles ND9000 family — Metso's valve business was spun off as Neles in 2020 and merged into Valmet in 2022, and is now sold under the Neles™ brand within Valmet Flow Control. This unit is a 4-20 mA + HART version with a stainless-steel Ex d enclosure, medium-capacity spool and ATEX+IECEx approval. The parameters below are taken from the Valmet/Neles original technical bulletin 7ND9021EN - 4/2025 for selection and spare-part verification.

I. Arrival Photos

Metso (Neles/Valmet lineage) ND9303HX smart valve positioner arrival photo 1
Arrival photo (taken by Baoman Industrial, watermarked, serial information redacted)

Metso (Neles/Valmet lineage) ND9303HX smart valve positioner arrival photo 2
Arrival and unboxing detail (taken by Baoman Industrial)

Metso (Neles/Valmet lineage) ND9303HX smart valve positioner arrival photo 3
Arrival and unboxing detail (taken by Baoman Industrial)

Metso (Neles/Valmet lineage) ND9303HX smart valve positioner arrival photo 4
Arrival and unboxing detail (taken by Baoman Industrial)

II. Brand & Model

ItemSpecification
【Brand lineage】Metso's valve and control business was spun off as Neles in 2020 and merged into Valmet in 2022; it is now sold under the Neles™ brand within Valmet Flow Control. This document follows the Metso to Neles/Valmet lineage to avoid confusion with the divested Metso brand
【Model】ND9303HX (ND9000 series smart valve positioner, 4-20 mA + HART, stainless-steel Ex d enclosure, medium-capacity spool, ATEX + IECEx hazardous-area approval)
【Model decoding】Per the original How to Order: ND = smart valve positioner; 9 = Series 9000 (VDI/VDE 3845 mounting face); 3 = stainless-steel Ex d, IP66/NEMA4X enclosure; 03 = medium-capacity spool (actuator volume 1-3 dm³); H = 4-20 mA + HART; X = ATEX + IECEx. Suffix positions for temperature, junction box, special construction and limit switch are generated by the original configuration software; not listed in the available materials, subject to the nameplate / purchase order or the official manual
【Product positioning】Intelligent valve positioner for every control-valve actuator, 32-bit MCU with contactless position sensing, for linear and rotary valves, single/double acting; device-level SIL 2 with HART / FOUNDATION Fieldbus / Profibus PA all native
【Manual source】Valmet/Neles original technical bulletin 7ND9021EN - 4/2025 (ND9000 Intelligent Valve Controller)
【Family distinction】ND9000 is the modulating smart positioner; NDX is the next-generation universal controller; NE700/NP700 are electro-pneumatic / pneumatic positioners; SG9000 is the on/off controller; VG9000 is the SIL 3 safety controller (SIS/PST)

III. Technical Data

The core parameters below are taken from the "Detailed Technical Data" and "How to Order" chapters of the Neles ND9000 original technical bulletin 7ND9021EN - 4/2025 (compiled from online official sources). Model ND9303HX is decoded digit by digit using the original coding table in that bulletin. Positions not published in the bulletin and outline dimensions not extractable from the drawings are marked "not listed in the available materials; subject to the nameplate / purchase order or the official manual", without assumption.

ItemSpecification
【Brand / model】Neles™ (within Valmet Flow Control, formerly Metso); ND9303HX = ND9000 series smart valve positioner, 4-20 mA + HART, stainless-steel Ex d enclosure, medium-capacity spool, ATEX + IECEx
【Nature / action】32-bit-microcontroller intelligent valve controller powered by 4-20 mA or fieldbus; double-acting or single-acting; contactless valve-position sensing
【Travel range】Linear 10-120 mm; rotary 45°-95°; feedback shaft free-rotation measuring range 110°
【Communication / input】HART, FOUNDATION Fieldbus (FF), Profibus PA (physical layer all to IEC 61158-2); HART version input 4-20 mA, minimum signal 3.6 mA, HART 6 or 7 selectable; FF/PA versions are fieldbus-powered
【Electrical data (HART)】Loop-powered 4-20 mA; maximum current 120 mA; burden voltage <= 9.7 VDC at 20 mA (approx. 485 ohm); maximum voltage 30 VDC; reverse-polarity protection -30 VDC; overcurrent protection > 35 mA
【Electrical data (FF / PA)】Supply 9-32 VDC (reverse-polarity protected); maximum base current 17.2 mA; quiescent current 16 mA; fault current (FDE) 3.9 mA
【Operating temperature】Standard -40 to +85 °C (-40 to +185 °F); Arctic option -53 to +85 °C (-64 to +185 °F); temperature effect on position 0.5 % / 10 K
【Air supply / air quality】Supply pressure 1.4-8 bar (20-115 psi); effect of 10 % inlet pressure change on position < 0.1 %; air quality per ISO 8573-1: particulates Class 5 (3-5 µm filtration recommended), humidity Class 1, oil Class 3 (< 1 ppm)
【Capacity / steady-state consumption】At 4 bar supply: spool 2 5.5 Nm³/h, spool 3 12 Nm³/h, spool 6 38 Nm³/h; steady-state consumption (4 bar) spool 2&3 < 0.6 Nm³/h, spool 6 < 1.0 Nm³/h; this unit uses spool 03 (medium, 1-3 dm³)
【Performance / vibration】Dead band <= 0.1 %; hysteresis < 0.5 % (medium constant-load actuator); vibration effect on position < 1 % (2g/5-150 Hz, 1g/150-300 Hz, 0.5g/300-2000 Hz)
【Enclosure / housing materials】IP66 / NEMA 4X; ND9300 housing is stainless steel (ND9100 epoxy-coated anodised aluminium + polymer composite, ND9200 epoxy-coated anodised aluminium + tempered glass, ND9400 stainless steel + polymer composite)
【Mounting / net weight】VDI/VDE 3845 mounting face (80x30-20, 80x30-30, 130x30-30, 130x30-50); conduit thread M20x1.5 (ND9000), 1/2 NPT for ND9000E2/U; net weight ND9100 1.8 kg, ND9200 3.4 kg, ND9300 8.6 kg, ND9400 5.6 kg; outline per original drawing, digit-by-digit values not listed in the available materials
【Diagnostics / local interface】Device self-diagnostics, online diagnostics, performance diagnostics, communication diagnostics, advanced diagnostics and data logging, third-generation diagnostics; local LUI with guided startup, automatic/manual linearisation calibration, one-point calibration and hot swap during process operation
【Approvals / SIL】SIL 2 approved device (device level); ATEX, IECEx, INMETRO, cCSAus, CCOE/PESO, KOSHA, NEPSI, CCC, etc.; explosion protection Ex ia/ib/ic/ec/nA, Ex d on selected models only (this unit's enclosure digit 3 is stainless-steel Ex d)

The knowledge-base entry "Neles Intelligent Valve Positioners and Valve Controllers" (entry_id 847323914710432a88bba1333739a2f7) contains the ND9000 detailed technical data table and the How to Order digit-by-digit decoding. That entry was compiled online by Baoman Industrial from the Valmet/Neles official website and original samples; the data were obtained via online search. Source: Valmet original technical bulletin 7ND9021EN - 4/2025 (https://www.valmet.com/globalassets/sharepoint/imported/7nd9021en.pdf, pp. 11-12, How to Order) and the Neles ND9000 official product page (https://www.valmet.com/flowcontrol/valve-automation/valve-controllers/neles-nd9000-intelligent-valve-controller/). Manual number 7ND9021EN - 4/2025. Positions and outline dimensions not published by the original manufacturer are not assumed and are subject to the nameplate / purchase order or the official manual.

IV. Related Models

ItemSpecification
Neles ND9100 / ND9200 / ND9400Same family, different enclosures/capacity: ND9100 standard aluminium 1.8 kg, ND9200 Ex d aluminium 3.4 kg, ND9400 stainless steel with polymer cover 5.6 kg, forming an enclosure ladder with the ND9300 (8.6 kg stainless-steel Ex d)
Neles NDXNext-generation modular intelligent valve controller with contactless magnetic sensing, stem travel up to 220 mm, low air consumption, graphical LUI, SIL 2 capable; bulletin 7NDX23EN - 2/2026
Neles NE700 / NP700NE700 electro-pneumatic positioner (4-20 mA, max. 190 ohm input impedance) and NP700 pneumatic positioner (20-100 kPa); economical, vibration-resistant general modulating duty
Neles SG9000 / VG9000SG9000 is the smart on/off controller (limit switches available up to SIL 3); VG9000 is the SIL 3 safety solenoid with partial-stroke testing (PST) per IEC 61508 / TÜV
Benchmark: Emerson FIELDVUE DVC6200Both are two-wire 4-20 mA, contactless position feedback, modular and HART-capable; the ND9000 has all three protocols native and declares device-level SIL 2, whereas the standard DVC6200 is HART only with FF/PA as separate variants

V. Selection Guide & Common Models

Selection guide:When selecting, first confirm from the order code the enclosure (digit 3 in this batch = stainless-steel Ex d), spool capacity (03 medium, 1-3 dm³), communication (H = 4-20 mA + HART) and hazardous-area approval (X = ATEX + IECEx), then verify supply pressure 1.4-8 bar, travel range, operating temperature and ISO 8573-1 air quality. For SIL loops, evaluate against the device-level SIL 2 and the assembly safety manual; limit switches requiring SIL2/3 need a qualified safety interface. Suffix positions for temperature, junction box and special construction not published by the manufacturer are subject to the nameplate / purchase order or the original configuration software. Please feel free to inquire for an item-by-item check against your actuator volume and service conditions.

Common models:This arrival: the Metso (now Neles™ / Valmet Flow Control) ND9303HX smart valve positioner. Parameters are compiled from the Valmet/Neles original technical bulletin 7ND9021EN - 4/2025 via online sources and are for selection and spare-part verification only, not guaranteed values. The specific configuration and approval codes are subject to the nameplate / purchase order or the official manual, and items not listed in the available materials are not assumed.

These are some of the configurations we supply regularly. If you are working through a selection, or would like to know about availability of these models, feel free to get in touch — we can look at the right combination together based on your operating conditions.

Disclaimer: The information above is not guaranteed to remain valid and may be modified without separate notice. Please confirm the latest information at the time of inquiry.

Ordering & Inquiry

The photos above show the models currently in stock. If you are working through a similar selection, or would like to know more about a model's configuration and availability, feel free to get in touch — we can look at the right combination together based on your valve type and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area