Rosemount 3051 & 3144/644 Transmitters - Arrival Photos & Technical Data
Baoman Industrial Technology (Chengdu) Co., Ltd. has recently received four specific Rosemount transmitter models: 3051TG3A2B21AS1KBQ4M5HR7 (3051TG gauge pressure transmitter), 3051GP3A2B21AB4M5Q4HR5 (3051GP gauge pressure transmitter), 3144PD6A2NAM5CQ4HR7 (temperature transmitter), and 644HAKBJ2M5Q4 (temperature transmitter). The technical data below come from an online search, source: Emerson official website, for selection reference.
I. Arrival Photos

Arrival photo (taken by Baoman Industrial, watermarked, serial information redacted)

Arrival and unboxing detail (taken by Baoman Industrial)

Arrival and unboxing detail (taken by Baoman Industrial)

Arrival and unboxing detail (taken by Baoman Industrial)

Arrival and unboxing detail (taken by Baoman Industrial)

Arrival and unboxing detail (taken by Baoman Industrial)

Arrival and unboxing detail (taken by Baoman Industrial)

Arrival and unboxing detail (taken by Baoman Industrial)
II. Brand & Model
| Item | Specification |
|---|---|
| Brand | Rosemount (an Emerson brand) |
| Model 1 received | 3051TG3A2B21AS1KBQ4M5HR7 — 3051TG gauge pressure transmitter |
| Model 2 received | 3051GP3A2B21AB4M5Q4HR5 — 3051GP gauge pressure transmitter |
| Model 3 received | 3144PD6A2NAM5CQ4HR7 — temperature transmitter |
| Model 4 received | 644HAKBJ2M5Q4 — temperature transmitter |
| Product category | 3051 series pressure transmitters (gauge pressure) and 3144PD / 644 temperature transmitters |
III. Technical Data
This shipment covers two categories: 3051 series pressure transmitters and 644 / 3144 temperature transmitters. The 3051TG / 3051GP are gauge pressure transmitters supporting multiple communication protocols with reference accuracy up to ±0.04%. The 3144PD / 644 temperature transmitters support universal sensor inputs, single / dual sensors and sensor matching, and can be head-mounted or rail / field-mounted. The data below are compiled from Emerson official website information.
| Item | Specification |
|---|---|
| Communication protocol (3051) | 4-20 mA HART / WirelessHART / FOUNDATION fieldbus / PROFIBUS / 1-5 V low-power HART |
| Reference accuracy (3051) | Up to ±0.04% |
| Turndown ratio (3051) | 150:1 |
| Stability (3051) | 10-year stability |
| Measurement range (3051) | Coplanar up to 4000 psi (275.79 bar); Inline up to 20000 psi (1378.95 bar) |
| Wetted materials (3051) | 316L SST / Alloy C-276 / Alloy 400 / tantalum / gold-plated alloy |
| Safety certification (3051) | SIL 2/3 (IEC 61508) |
| Warranty (3051) | 5-year warranty |
| Protocol (644/3144) | HART / FF / PROFIBUS PA |
| Mounting (644/3144) | Head-mounted (644H) / rail and field-mounted (3144PD / 644) |
| Input (644/3144) | Universal RTD / thermocouple / mV / Ω input, single / dual sensor |
| Output (644/3144) | 4-20 mA / HART, FF, PROFIBUS PA |
| Diagnostics (644/3144) | Hot Backup, sensor drift alarm, thermocouple degradation |
| Sensor matching (644/3144) | Callendar-Van Dusen constant sensor matching |
This data comes from an online search; source: Emerson official website (emerson.com). Parameters are subject to the latest official documentation.
IV. Related Models
| Item | Specification |
|---|---|
| 3051S | Rosemount 3051S series pressure transmitters, high-accuracy modular platform |
| 2051 | Rosemount 2051 series pressure transmitters, economical Coplanar platform |
| 4051S | Rosemount 4051S series pressure transmitters |
| 248 temperature transmitter | Rosemount 248 series temperature transmitters, economical head-mounted type |
V. Selection Guide & Common Models
Selection guide:Selection of the 3051 series starts with the measurement type (gauge / absolute / differential pressure) and measurement range (Coplanar up to 4000 psi, Inline up to 20000 psi), followed by the communication protocol (4-20 mA HART / WirelessHART / FF / PROFIBUS / 1-5 V low-power HART), wetted materials, reference accuracy (up to ±0.04%), whether SIL 2/3 certification is required, and the mounting form. For 644 / 3144 temperature transmitters, select by mounting (head-mounted 644H / rail and field-mounted 3144PD / 644), sensor type (RTD / thermocouple / mV / Ω), single / dual sensor, output protocol and diagnostic needs (Hot Backup, sensor drift alarm, thermocouple degradation, Callendar-Van Dusen matching). Please refer to Emerson official website information and confirm details at inquiry.
Common models:Four specific models in this shipment: 3051TG3A2B21AS1KBQ4M5HR7, 3051GP3A2B21AB4M5Q4HR5, 3144PD6A2NAM5CQ4HR7, 644HAKBJ2M5Q4.
These are some of the configurations we supply regularly. If you are working through a selection, or would like to know about availability of these models, feel free to get in touch — we can look at the right combination together based on your operating conditions.
Disclaimer: The information above is not guaranteed to remain valid and may be modified without separate notice. Please confirm the latest information at the time of inquiry.
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文