Baoman Industrial Technology (Chengdu) Co., Ltd. has recently received a shipment of Fisher i2P-100 electro-pneumatic transducers (including Type 646), which proportionally convert a 4-20 mA input into a pneumatic output to drive pneumatic control valve actuators or positioners, supporting natural gas supply and DIP-switch split ranging. Below are arrival photos and technical data for your reference.

I. Arrival Photos

Fisher i2P-100 electro-pneumatic transducer (including Type 646) arrival photo 1
Arrival photo (taken by Baoman Industrial, watermarked, serial information redacted)

Fisher i2P-100 electro-pneumatic transducer (including Type 646) arrival photo 2
Arrival and unboxing detail (taken by Baoman Industrial)

Fisher i2P-100 electro-pneumatic transducer (including Type 646) arrival photo 3
Arrival and unboxing detail (taken by Baoman Industrial)

Fisher i2P-100 electro-pneumatic transducer (including Type 646) arrival photo 4
Arrival and unboxing detail (taken by Baoman Industrial)

Fisher i2P-100 electro-pneumatic transducer (including Type 646) arrival photo 5
Arrival and unboxing detail (taken by Baoman Industrial)

II. Brand & Model

ItemSpecification
BrandFisher (an Emerson brand)
Modeli2P-100 electro-pneumatic transducer (DIP-switch split-range I/P); this shipment also includes the basic Type 646 I/P
FunctionProportionally converts a 4-20 mA DC input into a pneumatic output pressure to drive pneumatic control valve actuators or positioners
Input signalStandard 4-20 mA DC; split ranging (4-12 / 12-20 mA) settable via DIP switches
Output signal0.2-1.0 / 0.4-2.0 / 0.14-2.3 bar (DIP-switch range selection + zero / span potentiometer adjustment)
Supply mediumAir or natural gas (with third-party approval for use of natural gas as supply)

III. Technical Data

The i2P-100 is a compact electro-pneumatic transducer. Input split ranging is set via DIP switches and the output is adjusted with zero / span trim potentiometers (20 turns, located under the housing cover). The i2P-100 is the main model, with the basic Type 646 compared below.

ItemSpecification
Input signali2P-100: standard 4-20 mA, DIP-switch split range 4-12 / 12-20 mA; 646: 4-20 mA DC constant current, 30 V maximum constant-current output voltage
Output signali2P-100: 0.2-1.0 / 0.4-2.0 / 0.14-2.3 bar; 646: 0.2-1.0 bar (3-15 psig), direct action only
Reference accuracyi2P-100: ±1.0% of full scale (including hysteresis, linearity, dead band); 646: ±0.5% of full scale
Supply pressurei2P-100: 0.3 bar above output upper limit, 3.4 bar maximum; 646: 1.4 bar recommended, 3.4 bar maximum
Supply mediumi2P-100: air / natural gas; 646: air only (no third-party approval for natural gas)
Ambient temperaturei2P-100: -40 to 85 °C; 646: -40 to 71 °C
ConnectionsSupply / output / exhaust ports 1/4 NPT internal; electrical 1/2 NPT (646: 1/2-14 NPT) conduit connection; wire 18-22 AWG
Enclosure ratingi2P-100: CSA 4X/3X, FM NEMA 4X/3, ATEX IP66/IP64, IECEx IP66/IP64; 646: FM NEMA 3 / IP54, ATEX IP64
Weighti2P-100: 2.5 kg; 646: 1.6 kg
Certificationsi2P-100 / 646: CSA, FM, ATEX, IECEx, CUTR, INMETRO, KGS; i2P-100 additionally NEPSI, UKEx

Source: Fisher i2P-100 electro-pneumatic transducer instruction manual D103198X0CN; Type 646 instruction manual D101351X0CN. Parameters are subject to the latest official documentation.

IV. Related Models

ItemSpecification
646Basic I/P converter, accuracy ±0.5%, simple construction, air supply only
846Electronically self-calibrating I/P, accuracy ±0.30%, multiple ranges up to 2.3 bar, supports natural gas, IP66
546NSNuclear-grade electro-pneumatic transducer with Type 82 relay, high temperature and radiation resistance, indoor use only
67CFR filter regulatorMatching supply filter regulator for stable supply pressure

V. Selection Guide & Common Models

Selection guide:For conventional air supply and basic applications, choose the 646 (±0.5%, simple); for DIP-switch split ranging or natural gas supply, choose the i2P-100 (±1.0%); for wide range, high accuracy and harsh environments, choose the 846 (±0.30%, IP66); for nuclear / high-temperature high-radiation service, choose the 546NS. At ordering, confirm input signal range, output range and action, supply medium, enclosure rating and certification combination, mounting, and whether a 67CFR filter regulator is required.

Common models:i2P-100 (3-15 psi), i2P-100 (6-30 psi), i2P-100 (2-33 psi), and the basic Type 646.

These are some of the configurations we supply regularly. If you are working through a selection, or would like to know about availability of these models, feel free to get in touch — we can look at the right combination together based on your operating conditions.

Disclaimer: The information above is not guaranteed to remain valid and may be modified without separate notice. Please confirm the latest information at the time of inquiry.

Ordering & Inquiry

The photos above show the models currently in stock. If you are working through a similar selection, or would like to know more about a model's configuration and availability, feel free to get in touch — we can look at the right combination together based on your valve type and signal requirements.
Tel: +86 028-60220547  |  Email: info@bit-cd.com
Baoman Industrial Technology (Chengdu) Co., Ltd   Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

Application area