SAMSON 3730-6 Positioner with Pressure Monitoring - Technical Data
1. Product Overview
The SAMSON 3730-6 is an electro-pneumatic valve positioner with HART communication and pressure sensors. Based on the 3730-3 control platform, it integrates an online monitoring module for supply air pressure and output signal pressure, suitable for applications requiring diagnosis of air supply quality, valve output force and pressure alarms. Although it retains the "3730-X" naming prefix, it does not belong to the 3730-0~5 series: it is covered by a separate data sheet T 8384-6 EN, has a 14-digit ordering code, and its explosion-protection option set also differs from other 3730 models (including dedicated flameproof Ex d[ja] / Ex db[ja] options, codes 210 / 211).

SAMSON 3730-6 positioner official product image (official image, for selection reference only)
Arrival Photos (taken by Baoman Industrial)

SAMSON 3730 arrival photo, taken by Baoman Industrial, watermarked, identification details masked

SAMSON 3730 arrival photo, taken by Baoman Industrial, watermarked, identification details masked

SAMSON 3730 arrival photo, taken by Baoman Industrial, watermarked, identification details masked

SAMSON 3730 arrival photo, taken by Baoman Industrial, watermarked, identification details masked

SAMSON 3730 arrival photo, taken by Baoman Industrial, watermarked, identification details masked
2. Technical Description
Pressure monitoring: Integrated pressure sensors for online monitoring of supply air pressure and output pressure; standard configuration includes two programmable position alarms and one fault alarm contact, with status output as a condensed state according to NAMUR NE107, and measured values and diagnostic information readable via HART.
Control platform: Same platform as the 3730-3 — wear-free calibrated position sensor, analog i/p module and pneumatic amplifier, microprocessor; supports four initialization modes and sub-initialization, parameters stored in EEPROM, with continuous zero-point monitoring, tight shut-off function, temperature sensor and operating hours counter. Two-wire load approximately 460 Ω.
Safety version: The 3730-6 TS (TROVIS SAFE) is a switch-type safety version for SIS safety instrumented systems, using the same 14-digit code structure; the "function" digit can select an emergency shut-off threshold (≤3.8 mA or ≤4.4 mA).
Ordering code structure: Complete ordering number = 3730-6 + 14 digits; in the mask, explosion protection occupies the initial 3 digits (P1-P3), two digits fewer than the 16 digits of the 3730-3/4/5. Do not apply the 16-digit digit table of the 3730-3.
3. Key Technical Data
| Item | Description |
|---|---|
| Input signal | 4-20 mA two-wire, reverse polarity protected, minimum span 4 mA; HART superimposed |
| Load impedance | ≤9.2 V (460 Ω at 20 mA) |
| Supply air pressure | 1.4-7.0 bar |
| Travel range | 3.6-300 mm (linear, depending on mounting) |
| Rotation angle range | 24°-100° (rotary) |
| Accuracy | Hysteresis ≤0.3%; sensitivity ≤0.1%; characteristic deviation ≤1% |
| Pressure monitoring | Integrated supply air and output pressure sensors, supporting online monitoring and alarms; HART can upload pressure measured values |
| Degree of protection | IP66 / NEMA 4X |
| Type of explosion protection | Mainly intrinsically safe Ex ia; including dedicated flameproof Ex d[ja] / Ex db[ja] (codes 210 / 211), dust, Ex nA, etc. |
| Self-diagnostics | EXPERTplus, NE107 status indication |
| Ambient temperature | -20 ~ +80 °C (metal cable gland -45 ~ +80 °C; explosion protection subject to the certificate) |
| Ordering code length | 14 digits (separate data sheet T 8384-6 EN) |
| Functional safety | Complies with IEC 61508, can be used in SIL 2 (single) / SIL 3 (redundant) |
4. Selection Guide (Complete Ordering Code)
Complete ordering number = 3730-6 + 14 digits, explosion protection occupies the initial 3 digits (P1-P3). The table below lists the available codes and meanings digit by digit (positions marked "※" are inferred from the official table; final confirmation with the official selection/ordering tool is recommended):
| Position | Item | Available codes / Meaning |
|---|---|---|
| P1-P3 | Explosion protection (3 digits) | 000 = no explosion protection; 110 = ATEX II 2G Ex ia IIC T6 Gb / II 2D Ex ia IIIC T80°C Db; 111 = IECEx Ex ia; 112 = CCC / NEPSI Ex ia IIC T4-T6 Gb; 130 = FM intrinsically safe; 131 = CSA Ex ia; 210 = ATEX II 2G Ex d[ja] IIC T6 Gb (flameproof, dedicated); 211 = IECEx Ex db[ja] IIC T6 Gb (flameproof, dedicated); 510 / 511 = dust Ex tb; 810 / 811 / 816 = Ex nA / Ex nL / Ex tc |
| P4 | Inductive limit switch | 0 = none; 10 = SJ2-SN (NC contact) |
| P5 | Forced venting / solenoid valve | 0 = none; 1 = solenoid valve 24 V DC; 2 = forced venting 24 V DC |
| P6-P7 | Other equipment (additional) | 00 = none; 10 = position transmitter; 20 = leak sensor (incl. cable and fixing screws); 30 = digital input; 11 = separate position sensor (incl. 10 m cable); 02 = reserved connection, no sensor included |
| P8※ | Function | 0 = standard (control valve); 1 = emergency shut-off (3.8 mA / 4.4 mA, 3730-6 TS safety version) |
| P9※ | Housing material | 1 = aluminum (standard); 2 = stainless steel 1.4408 |
| P10※ | Special application | 0 = none; 1 = paint-compatible; 2 = rear sealing + 1/4-18 NPT vent port; 6 = with additional vent hole + VDI/VDE 3847 adapter; 7 = with additional vent hole |
| P11-P14※ | Reserved / fixed positions | Fill in according to the data sheet; usually 0 for standard orders |
5. Complete Model Enumeration
The following is a list of complete 14-digit ordering codes for the 3730-6. The meaning of the initial 3 explosion-protection digits has been verified against T 8384-6 EN; the remaining digits are shown as standard configuration illustrations; for formal orders, the code generated by the official selection tool shall prevail (please consult us for confirmation):
| Complete ordering code | Digit-by-digit breakdown / Meaning |
|---|---|
3730-6 11000000000000 | Initial 3 explosion-protection digits 110 = ATEX intrinsically safe Ex ia IIC T6 Gb / II 2D Ex ia IIIC T80°C Db; P4=0 no limit switch; P5=0 no solenoid valve/forced venting; P6-P7=00 no additional equipment; P8-P14 are standard configuration illustrations (please consult us for confirmation) |
3730-6 11200000000000 | Initial 3 explosion-protection digits 112 = CCC / NEPSI Ex ia IIC T4-T6 Gb (China explosion protection); remaining digits standard configuration illustration (please consult us for confirmation) |
3730-6 21000000000000 | Initial 3 explosion-protection digits 210 = ATEX II 2G Ex d[ja] IIC T6 Gb (flameproof, exclusive option of T 8384-6 EN); remaining digits standard configuration illustration (please consult us for confirmation) |
Note: The 3730-6 uses a 14-digit code (3 explosion-protection digits + 11 following digits), different from the 16 digits of the 3730-3/4/5. Do not assemble codes by yourself for positions marked "Please consult us for confirmation".
6. Related Models
| Related model | Type / Application |
|---|---|
| 3730-3 | HART full-featured type (no pressure sensor), 16-digit code, T 8384-3 EN |
| 3730-6 TS | TROVIS SAFE safety version of the 3730-6, for SIS switch-type safety applications |
| 3731-3 / 3731-5 | Ex d flameproof HART / FF positioners (15-digit codes, T 8387-3 EN / T 8387-5 EN) |
| 3730-4 / 3730-5 | PROFIBUS PA / FOUNDATION Fieldbus fieldbus types |
| 3725 | Digital basic positioner, 10-digit ordering code, intrinsically safe Ex ia |
7. Common Spare Parts
| Component | Description / Part number |
|---|---|
| Position sensor assembly | Part number: please consult us for confirmation |
| Pressure sensing module (supply / output) | Part number: please consult us for confirmation |
| i/p converter | Part number: please consult us for confirmation |
| Pneumatic amplifier | Part number: please consult us for confirmation |
| Display and operating unit (LCD and buttons) | Part number: please consult us for confirmation |
| Housing and cover assembly | Part number: please consult us for confirmation |
8. Matching Accessories
| Accessory | Model / Specification | Application |
|---|---|---|
| Filter pressure-reducing valve | Please consult us for confirmation | Filters and stabilizes the instrument air supply pressure |
| Position transmitter | Please consult us for confirmation | Outputs 4-20 mA valve position feedback signal |
| Inductive limit switch | SJ2-SN (normally closed contact) | Limit position feedback |
| Solenoid valve / forced venting assembly | 24 V DC | Emergency action / forced venting |
| Leak sensor | Please consult us for confirmation | Valve seat leakage monitoring |
| Separate position sensor | Please consult us for confirmation | Position detection for separate actuator mounting |
| Reversing amplifier | 3710 | For use with double-acting actuators |
| Commissioning software | TROVIS-VIEW (SSP interface) / DTM | Parameter setting, commissioning and diagnostics |
9. Disclaimer
The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry.
10. Sources & Contact
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China