| SAMSON 3730 Smart Electropneumatic Positioner - Complete Technical Data | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Release time:2026-11-20 00:46:35 | Views: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
The SAMSON 3730 series of smart electropneumatic positioners covers non-communication, HART, PROFIBUS PA and FOUNDATION Fieldbus versions, built on a hybrid platform with analog PD control plus a microprocessor. It offers LCD display, autotuning and EXPERT / EXPERTplus diagnostics. This article covers its technical data, ordering code structure and selection points. I. Product Positioning
The 3730 series is designed for linear and rotary pneumatic control valves. It can be mounted directly on SAMSON Type 3277 actuators, or on IEC 60534-6-1 (NAMUR) and VDI/VDE 3845/3847 interfaces. The pressure-monitoring 3730-6 and the flameproof 3731 series are separate designs, covered by T 8384-6 EN and T 8387-3/5 EN respectively. Source: SAMSON official data sheets T 8384-3/4/5 EN and NA 0122; related data sheets T 8384-6 EN, T 8387-3 EN and T 8387-5 EN. Parameters are subject to the latest official data.
Arrival Photos (taken by Baoman Industrial)
II. Core Technical Data
Source: SAMSON official data sheets T 8384-3/4/5 EN and NA 0122. III. Communication Versions & Model Differences
The 3730-6 adds supply and output pressure monitoring on the 3730-3 platform, uses a 14-digit order code and is covered by T 8384-6 EN. The 3731 series is the flameproof (Ex d) version of the corresponding 3730 models; its ordering code follows T 8387-3/5 EN and must not be derived from the 3730 digit tables. Source: SAMSON official data sheets T 8384-3/4/5 EN, T 8384-6 EN and T 8387-3/5 EN. IV. Ordering Code StructureA complete order number consists of "3730-X" followed by numeric digits in grouped positions, typically 16 digits. Taking the 3730-3 (HART) as an example: P1 is explosion protection (0 none, 1 ATEX intrinsically safe, 3 CSA, 5 dust only, 8 Ex nA); P2 is the inductive limit switch (0 none, 1 SJ2-SN normally closed); P3 is the solenoid valve (0 none, 4 with 24 V DC); P4-P7 are a mutually exclusive additional-device group (position transmitter, remote position sensor, analog input, leakage sensor, digital input); P8 is diagnostics (0 standard EXPERT, 4 EXPERTplus); P10 is housing material (0 aluminum, 1 stainless steel); P13 is special application; P15-P16 are special certification combinations. Example: 3730-3 1001000400000000 indicates ATEX intrinsic safety, a position transmitter (4-20 mA position feedback), EXPERTplus diagnostics and a standard aluminum housing. If a discrete limit switch is required instead, P2 is set to 1. For the 3730-4 and 3730-5, the 4th digit is fixed at 0 as a bus identifier; for the 3730-5, explosion protection occupies four digits: P1 and P14-P16. The complete code should be confirmed with the SAMSON official selection / ordering tool. Source: SAMSON official data sheets T 8384-3/4/5 EN and NA 0122; inferred digit positions should be confirmed with the official ordering tool. V. Selection Points & Precautions1. Choose the base model by communication: non-communication 3730-0/1/2, HART 3730-3, PROFIBUS PA 3730-4, FOUNDATION Fieldbus 3730-5; for pressure monitoring see the 3730-6, and for safety instrumented applications see the 3730-6 TS or the 3731 series. 2. Fill in the explosion protection digit according to site certification requirements; this series is mainly intrinsically safe Ex ia with no Ex d, so choose the 3731 series when flameproof enclosure is required. 3. Add options in the corresponding positions as needed: inductive position switch, solenoid valve, remote position sensor, leakage sensor, digital input and position transmitter. 4. The 3730-3/4/5 have the same digit count but different explosion coding and dedicated options, so their digit tables cannot be interchanged. VI. Selection Guide & Common ModelsSelection guide: The 3730 series follows the sequence "communication first, explosion protection second, options last". Determine the fieldbus or HART requirement, then select the certification code against data sheet T 8384-x, then add feedback, switches and solenoid valves as needed, and finally confirm the 16-digit code with the official selection tool. If a flameproof housing or online pressure monitoring is required, move to the 3731 series or the 3730-6 rather than assuming these functions on the 3730-0/1/2/3/4/5. Common models: 3730-3 (HART, widely used), 3730-1 and 3730-2 (non-communication digital versions), 3730-4 (PROFIBUS PA), 3730-5 (FF), plus configurations with position feedback and EXPERTplus diagnostics; related series include the 3730-6 (pressure monitoring) and 3731-3 / 3731-5 (flameproof). If you are specifying a positioner for a valve, or want to confirm the 3730 communication version, explosion protection code and options, please feel free to contact us. We can check the model and ordering code together against your protocol, mounting and certification requirements. Orders & InquiriesBaoman Industrial Technology (Chengdu) Co., LtdTel: +86 028-60220547 | Email: info@bit-cd.com Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry. |