Fisher FIELDVUE DVC2000 Digital Valve Controller | Technical Data & Configuratio
The performance and simplicity of the Fisher FIELDVUE DVC2000 instrument allows for your operation to run closer to setpoint, improving product quality with more accurate control. Using FIELDVUE Performance Diagnostics, valve operation is monitored online to evaluate performance and reliability.
1. Product Overview
This page focuses on the four diagnostic tiers of the Fisher FIELDVUE DVC2000 — AC / HC / AD / PD (ordering-code segment 6). DVC2000 is an entry-level digital valve controller supporting HART 5 (4-20 mA input), single-acting, with built-in LCD and 4-key LUI, using Hall-effect non-contact position feedback.
All four tiers share the same hardware platform; they differ in the depth of diagnostics and communication — from basic auto-calibration (AC) to online performance diagnostics (PD).






2. Technical Description
Diagnostic level (segment 6) — focus of this page:
• AC (Auto-Calibration): basic positioner function, remote interaction via HART communicator;
• HC (HART Communication): basic HART communication, alarms, ValveLink™ compatible;
• AD (Advanced Diagnostics): HART comm. + offline diagnostics (requires ValveLink);
• PD (Performance Diagnostics): AD + online diagnostics (requires ValveLink).
Communication: HART 5 (4-20 mA input, single-acting); loop minimum 8.5 V DC (9.0 V DC for HART).
Position feedback: Hall-effect non-contact; optional 4-20 mA transmitter + discrete switch (code 5B).
Configuration: HART communicator 375/475 or ValveLink™ software.
3. Main Technical Specifications
| Parameter | Specification / Description |
|---|---|
| Basic model | DVC2000 (HART 5, 4-20 mA, single-acting); this page covers AC/HC/AD/PD tiers |
| Diagnostic level | AC auto-cal / HC HART comm. / AD advanced (offline) / PD performance (online) |
| Input signal | 4-20 mA DC; loop minimum 8.5 V DC (9.0 V DC for HART) |
| Supply pressure (max inlet) | 100 psi (7 bar) |
| Position feedback | Optional 4-20 mA transmitter + discrete switch (code 5B) |
| Enclosure rating | NEMA 4X / CSA Type 4X / IEC 60529 IP66 |
| Ambient temperature | -40 to +80 °C |
| Construction / display | Aluminum; 4-key LUI + LCD local display |
| Mounting standard | NAMUR, IEC 60534-6-1, IEC 60534-6-2 |
| Hazardous-area approvals | CENELEC, CSA, FM, ATEX, IECEx, GOST-R, INMETRO, KGS, NEPSI, PESO CCOE, RTN |
4. Selection Guide (ordering code by segment)
Based on the DVC2000 8-segment code, segment ⑥ selects the diagnostic tier:
| Tier | Meaning | Capability |
|---|---|---|
| AC | Auto-calibration | Basic positioner function, remote interaction via HART communicator |
| HC | HART communication | Basic HART communication, alarms, ValveLink compatible |
| AD | Advanced diagnostics | HC + offline diagnostics (requires ValveLink) |
| PD | Performance diagnostics | AD + online diagnostics (requires ValveLink) |
| Other seg | Field | Common codes |
|---|---|---|
| ① | Hazardous area | 1A CSA / 1B FM / 1C ATEX Ex ia / 1D IECEx / 1G NEPSI etc. |
| ② | Housing | 2A housing B (standard); 2B housing A (Fisher GX only) |
| ③ | Connections | 3A 1/2 NPT+1/4 NPT; 3B M20+G1/4; 3C/3D/3E adapters |
| ④ | Working pressure | 4A 1.3-3.3 barg; 4B 3.4-7.0 barg |
| ⑤ | Feedback | 5A none; 5B 4-20 mA transmitter + discrete switch |
| ⑦ | LUI language | EN/CH/DE/ES/FR/IT/JA/PT/RU/PO/CZ/AR |
| ⑧ | Other options | XX none; SF filter; VC remote exhaust; CG seal; HF HART filter; PP plugs; CC custom |
Example: DVC2000 1C_2A_3A_4B_5B_PD_CH_SF (ATEX IS, housing B, 1/2+1/4 NPT, 3.4-7.0 barg, with feedback, PD performance diagnostics, Chinese LUI, 10 μm filter). Consult for any unclear segment.
5. Complete Model Enumeration
| Tier | Model / Description |
|---|---|
| AC auto-cal | DVC2000…AC… (basic positioner function) |
| HC HART comm. | DVC2000…HC… (basic HART communication, alarms) |
| AD advanced | DVC2000…AD… (with offline diagnostics) |
| PD performance | DVC2000…PD… (with online diagnostics, focus) |
| High-end alt. | DVC6200H/F/P (10 segments, multi-protocol, ODV) |
Historic / supply models (original information retained):
| Model / Configuration |
|---|
| Home > Products > Fisher > DVC2000 Digital Valve Controller |
| DVC2000 | DVC2000AC | DVC2000HC | DVC2000AD | |
| DVC2000PD | DVC6000 | DVC6010 | DVC6020 | |
| DVC6030 | DVC6010AC | DVC6010HC | DVC6010AD | |
| DVC6010PD | DVC6020AC | DVC6020HC | DVC6020AD | |
| DVC6020PD | DVC6030AC | DVC6030HC | DVC6030AD | |
| DVC6030PD | DVC6010FCFD | DVC6010LCFD | DVC6010SCFD | |
| DVC6020FCFD | DVC6020LCFD | DVC6020SCFD | DVC6030SCFD | |
| DVC6010F | DVC6020F | DVC6030F | DVC6005/6025PD | |
| GG12361X012 | For 657/667 SIZE 70/76/87 (fits DVC2000/DVC6200) | |
6. Related Models
Related: DVC2000 (base page), DVC6200H/F/P (mid-to-high end multi-protocol), Gulde 3800SA (Chinese-interface rebadge). Higher diagnostic tiers provide richer information (PD supports online diagnostics), requiring ValveLink software.
7. Common Spare Parts
| Spare | Part number / Description |
|---|---|
| Repair kit | Consult Emerson by nameplate serial number |
| 10 μm integral air filter | Option SF |
| HART filter | Option HF |
8. Accessories
Accessories: filter regulator (e.g. Fisher 67CFR), mounting brackets and magnet, HART communicator 375/475, ValveLink™ software (required for AD/PD), intrinsic safety barriers/isolators.
9. Disclaimer
The above information is not guaranteed to remain valid and is subject to change without notice. Please confirm the latest information at the time of inquiry; certification status, production status and specific ordering codes should be verified with the manufacturer.
10. Sources & Contact
We supply the above models and the listed spare parts and accessories. For selection or supply inquiries, please consult +86 028-60220547 / info@bit-cd.com
Ordering & Inquiry
Baoman Industrial Technology (Chengdu) Co., Ltd Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

简体中文
ENGLISH