Home » Service & Support » Technical Documentation
Fisher 92B Steam Regulator Safety Override Pilot (6492HM/HTM) Selection Guide
Release time:1970-01-01 08:33:46 | Views:

The Fisher 92B is an industrial standard steam pressure reducing valve. Where it is not appropriate to install a vent pipe, a Type 6492HM or 6492HTM safety override pilot can be equipped to prevent the downstream pressure from exceeding the safe operating pressure. This article covers the safety override system principle, key selection parameters, differential pressure and temperature limits and certification status, based on the official Fisher manual and bulletin.

I. Product Positioning

ItemDescription
BrandFisher (Emerson)
Series92B
TypeIndustrial standard steam pressure reducing valve
Safety optionType 6492HM / 6492HTM safety override pilot
System approvalASME B31.1-1989 122.14.2.A
Main official documentsInstruction Manual D100703X012 (Type 92B, 2019-07); Bulletin 71.2:92 D101342X012; Instruction Manual D104687X012; Bulletin D104686X012

Source: Fisher official Instruction Manual D100703X012 (Type 92B, 2019-07), Bulletin 71.2:92 D101342X012, Instruction Manual D104687X012 and Bulletin D104686X012.

Fisher 92B steam pressure reducing valve
Official product image, for selection reference only

II. Safety Override System Principle

The safety override pilot is installed in series on the upstream valve and continuously monitors the pressure downstream of the second valve. When the downstream reducing valve fails and the pressure rises to the setpoint, the override pilot actuates to shut off or limit the upstream pressure, preventing downstream overpressure. This system is approved under ASME B31.1-1989 122.14.2.A and can replace an ASME safety valve where it is inconvenient to install a vent pipe and the upstream steam pressure does not exceed 400 psig / 27.6 bar.

III. Key Selection Parameters of the 92B

ItemParameter
Body sizeNPS 1, 1-1/2, 2, 3, 4 / DN 25, 40, 50, 80, 100
End connectionNPT, BSPT, CL125 FF, CL150 RF, CL250 RF, CL300 RF, PN 16/25/40
Maximum inlet pressure300 psig / 20.7 bar
Maximum outlet pressure250 psig / 17.2 bar
Spring range2 to 250 psig / 0.138 to 17.2 bar
Pressure sensingExternal pressure sensing
Body materialCast iron, steel, stainless steel
Maximum temperature353 to 600°F / 178 to 316°C (depending on construction)

IV. Differential Pressure and Temperature Limits

ConfigurationMaximum valve differential pressureMinimum differential pressure at full travel
Threaded / CL250 flanged (NPS 1~2)248 psi20 psig (stainless steel spring) / 10 psig (Inconel spring)
CL125 flanged123 psiSame as above

V. Certification Status

The official 92B bulletin lists the PED Classification Guide as a related resource, but no separate PED/ATEX statement is provided in the official full text. Please confirm the specific certification status with Emerson.

Source: Fisher official Instruction Manual D100703X012 (Type 92B, 2019-07), Bulletin 71.2:92 D101342X012, Instruction Manual D104687X012 and Bulletin D104686X012.

VI. Selection Guide & Common Models

Selection guide: First determine the 92B body size (NPS 1, 1-1/2, 2, 3, 4 / DN 25, 40, 50, 80, 100), end connection (NPT, BSPT, CL125 FF, CL150 RF, CL250 RF, CL300 RF, PN 16/25/40) and spring range (2 to 250 psig / 0.138 to 17.2 bar) for the steam duty, then check against the maximum inlet pressure of 300 psig / 20.7 bar, maximum outlet pressure of 250 psig / 17.2 bar and the differential pressure and temperature limits. Pressure sensing is external, body materials are cast iron, steel and stainless steel, and the maximum temperature is 353 to 600°F / 178 to 316°C depending on construction. Where it is inconvenient to install a vent pipe and the upstream steam pressure does not exceed 400 psig / 27.6 bar, a Type 6492HM or 6492HTM safety override pilot can be equipped to replace an ASME safety valve; please confirm the specific certification status with Emerson.

Common models: 92B self-powered steam pressure regulator, used with 6492HM / 6492HTM safety override pilots; common bodies and end connections selected by size and differential pressure. Please confirm the specific certification status with Emerson.

If you are specifying a steam reduction or safety override solution, or would like to know about availability of the 92B and its pilots, please feel free to contact us. We can help check the right combination against your differential pressure, temperature and size requirements.

Orders & Inquiries

Baoman Industrial Technology (Chengdu) Co., Ltd
Tel: +86 028-60220547 | Email: info@bit-cd.com
Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China

The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry.