| Fisher 630 / 630R Regulator & Relief Valve Field Conversion Guide | ||||||||||||||||||||||||||||||||||
| Release time:1970-01-01 08:33:46 | Views: | ||||||||||||||||||||||||||||||||||
The Fisher 630 Big Joe series includes the self-operated, spring-loaded 630 pressure reducing regulator and the 630R relief valve. The two can be converted into each other in the field, but the conversion involves replacement of internal parts and must be carried out in accordance with the official instruction manual. This article covers their structure and working principle, field interchangeability requirements, allowable pressure drop versus disk material and selection points, based on the official Fisher documentation. I. Product Positioning
Source: Fisher official Instruction Manual D100300X012 (Form 1243); Bulletin 71.4:630R.
II. Structure and Working PrincipleThe 630 is a self-operated regulator with a maximum design inlet pressure of 1500 psig / 103 bar and an outlet pressure of 3 to 500 psig / 0.21 to 34.5 bar. It features sour gas service capability and is suitable for primary farm-tap or high-pressure industrial regulation. The 630R is the relief version of the same series, with a relief setting range of 3 to 250 psig. III. Internal Parts Requirements for Field Interchangeability
IV. Allowable Pressure Drop vs. Disk Material
V. Selection TipsOrifice sizes 1/8, 3/16, 1/4, 3/8, 1/2 in (3.18-12.7 mm); body 1" and 2" / DN 25 and 50; end connections NPT, ASME CL150 RF, CL300 RF, CL600 RF. The medium is natural gas, air or compatible gases. NACE materials are optional, and the official documentation notes that the 630 series has been evaluated for hydrogen service. Certifications such as PED/ATEX/UL are not explicitly stated in the official instruction manual; please confirm with Emerson. Source: Fisher official Instruction Manual D100300X012 (Form 1243); Bulletin 71.4:630R. VI. Selection Guide & Common ModelsSelection guide: First decide whether the duty requires the 630 pressure reducing regulator or the 630R relief valve, then confirm the orifice size, body size and end connection against inlet pressure, outlet setpoint and medium: orifice sizes 1/8, 3/16, 1/4, 3/8, 1/2 in (3.18-12.7 mm), bodies 1" and 2" / DN 25 and 50, end connections NPT, ASME CL150 RF, CL300 RF and CL600 RF. Converting a 630 to a 630R requires replacing the valve carrier, disk and orifice, resetting to the 3 to 250 psig relief range and performing setting and leakage verification in accordance with the instruction manual; the medium temperature range is determined by the disk material. NACE sour-gas materials are optional; certifications such as PED/ATEX/UL are not explicitly stated in the official instruction manual, so please confirm with Emerson. Common models: 630 (self-operated pressure regulator), 630R (relief version in the same series, convertible from the 630 by changing internal parts); orifice sizes 1/8, 3/16, 1/4, 3/8, 1/2 in; bodies 1″ / 2″ (DN25 / DN50); end connections NPT, ASME CL150/CL300/CL600 RF; NACE sour-gas materials optional. If you are specifying a regulator for natural gas or air service, or would like to know about availability of the 630 / 630R and internal parts, please feel free to contact us. We can help check the right orifice and materials against your inlet pressure, outlet setpoint and media. Orders & InquiriesBaoman Industrial Technology (Chengdu) Co., LtdTel: +86 028-60220547 | Email: info@bit-cd.com Address: Room 1108, Building A, Tingbiao Central Plaza, No. 158 Erxianqiao East Road, Chenghua District, Chengdu, Sichuan Province, China The information above is not guaranteed to remain valid at all times. Subsequent changes will not be notified separately. Please confirm the latest information at the time of inquiry. |

简体中文