Fisher 4210 Electronic Position Transmitter 4-20mA with High/Low Position Switch
The Fisher 4210 electronic position transmitter senses actuator position and sends a standard 4-20 mA output with high/low electrical position switches. The 4200 series was discontinued in 2025 and replaced by the Fisher FIELDVUE 4400.
Disclaimer: The information above is subject to change without prior notice. Please confirm the latest details with us at the time of inquiry.
Product Overview
The Fisher 4210 electronic position transmitter belongs to the Fisher 4200 series. Combining Fisher's field-proven electronic and mechanical technologies, it senses the position of linear actuators, rotary actuators, vents, dampers or other devices, and sends a standard 4-20 mA output signal to indicating devices, process control systems or programmable logic controllers (PLC). The 4210 provides both transmitter and high/low electrical position switch functions, delivering analog and discrete alarm electrical signals in one unit.
| Product Series | Fisher 4200 series electronic position transmitter |
|---|---|
| Configuration of this model | Transmitter + high/low electrical position switches (standard stroke) |
| Output signal | 4-20 mA DC (analog) + SPDT relay contacts (discrete alarm) |
| Applicable stroke | Standard stroke up to 105 mm (4.125 in) |
| Reference accuracy | ±1% of output span |
| Enclosure protection | NEMA 4X / CSA Type 4X / IP66 |
| Mounting | Linear or rotary valve actuators, or other devices |
Discontinuation and Replacement
Technical Description
● Three configurations: transmitter only; transmitter with integrated high/low position switches; or high/low position switches only. See the nameplate and model table for the specific type.
● Position sensing: after installation, the potentiometer shaft is mechanically linked to the device to sense movement. All types except the 4215 use a single potentiometer as the position input; the 4215 uses a coaxial dual potentiometer to provide additional electrical isolation between the transmitter and switch circuits.
● Long-travel applications: a multi-turn potentiometer is connected to the travel sensor assembly to sense linear motion of the actuator stem or other devices.
● Switch outputs: two SPDT relays rated 5 A @ 30 V DC or 120 V AC (resistive), with a rated load life of 100,000 cycles.


Specifications
| Item | Specification |
|---|---|
| Output signal | 4-20 mA DC (4210 / 4211 / 4215 / 4220 / 4221) |
| Output current limit | 30 mA DC (maximum) |
| Reference accuracy | ±1% of output span (including combined effects of hysteresis, linearity and dead band) |
| Repeatability | ±0.25% of span |
| Position switch relays | Two SPDT relays; contacts rated 5 A @ 30 V DC or 120 V AC (resistive); rated load life 100,000 cycles, 50,000 cycles under 10 A inrush lamp/motor loads |
| Power supply | Transmitter only: 11-30 V DC / 20 mA max; transmitter with position switches: 20-30 V DC / 80 mA max; switches without transmitter: 20-30 V DC / 50 mA max. 24 V DC nominal recommended |
| Ambient temperature | Operating -40 to 71 °C (-40 to 160 °F); transportation/storage -50 to 80 °C (-60 to 180 °F) |
| Relative humidity | 10% to 95% (operating and transportation/storage) |
| Electromagnetic compatibility (4211/4221) | EN 61326-1:2013; industrial location immunity; Class A emissions |
| Enclosure protection | NEMA 4X; CSA Type 4X; IP66 |
| Mounting | Linear or rotary valve actuators, or other devices |
4200 Series Model Configuration
| Model | Transmitter | Electrical position switches | Standard stroke (≤105 mm) | Long stroke (≤610 mm) | Dual potentiometer |
|---|---|---|---|---|---|
| 4210 | ✓ | ✓ | ✓ | — | — |
| 4211 | ✓ | — | ✓ | — | — |
| 4212 | — | ✓ | ✓ | — | — |
| 4215 | ✓ | ✓ | ✓ | — | ✓ |
| 4220 | ✓ | ✓ | — | ✓ | — |
| 4221 | ✓ | — | — | ✓ | — |
| 4222 | — | ✓ | — | ✓ | — |
Long-stroke models (4220/4221/4222) achieve travels up to 305 mm / 610 mm via 12-inch / 24-inch travel converters. Zero and span limits are detailed in Table 3 of the manual.
Certifications
| Certifying body | Protection type |
|---|---|
| CSA | Intrinsically safe, flameproof, dust ignition-proof |
| FM | Intrinsically safe, flameproof, dust ignition-proof, nonincendive |
| ATEX | Intrinsically safe, type n, flameproof |
| IECEx | Intrinsically safe, type n, flameproof |
Other classifications/certifications: CUTR, KGS, PESO. Please consult us for specific classification and certification details; the product nameplate and official Emerson documentation prevail.
Related Models
| Model | Description |
|---|---|
| Fisher FIELDVUE 4400 | Official successor to the 4210; linkless non-contact feedback, HART 7 communication, SIL 2 capability (exida certified per IEC 61508:2010), with two solid-state limit switches |
| Fisher 4211 | 4200 series transmitter-only configuration (no position switches) |
| Fisher 4215 | Dual potentiometer isolated version (transmitter + switches) |
| Fisher 4220 / 4221 / 4222 | Long-stroke versions (up to 610 mm) |
| Fisher FIELDVUE DVC6200 | Intelligent digital valve controller (positioning + diagnostics), available from our regular stock |
Spare Parts (serial number required for ordering)
| Maintenance kit part number | Applicable models |
|---|---|
| R4210CBX012 (control board maintenance kit) | 4210 / 4220 |
| R4211CBX012 (control board maintenance kit) | 4211 / 4221 |
| R4212CBX012 (control board maintenance kit) | 4212 / 4222 |
| R4215CBX012 (control board maintenance kit) | 4215 |
| R4210PSX012 (potentiometer/bushing maintenance kit) | 4210 / 4211 |
| R4220PSX012 (potentiometer/bushing maintenance kit) | 4220 / 4222 |


Accessories and Installation
● Mounting bracket: the transmitter is mounted on the actuator via a mounting bracket; allow 254 mm (10 in) clearance for cover removal during maintenance.
● Travel converters: 12-inch / 24-inch travel converters are available for long-stroke models.
● Field wiring: the wiring compartment provides two 1/2 NPT electrical connections (one on each side).
● Installation difference notice for the replacement model: the 4400 uses linkless non-contact feedback; a magnet strip must be ordered separately (supplied apart from the transmitter), and its mounting method differs from the 4200 series — the dedicated 4400 mounting kit must be used, and the 4200 brackets and procedures cannot be reused.